TM 9-2320-364-20-2
2-1180
5. GAGE(S) GIVING NO OR INCORRECT READINGS (CONT).
2.
Repair wire 1276 (see
schematic Fig 2-26)
or notify DS
Maintenance.
Verify repair, go to
Step 7 of this Fault.
YES
NO
Wipers operate indicating
10 to 14 vdc to circuit breakers
CB10 and CB8.
Circuit breakers CB8 and CB10
not tripped.
Gage wire 1276 faulty.
Wire 1435 faulty.
Sending wire faulty.
Gage faulty.
Sending unit faulty.
Dash lock up circuit breaker
CB8 faulty.
Wire 1276 faulty.
KNOWN INFO
POSSIBLE PROBLEMS
TEST OPTIONS
REASON FOR QUESTION
Voltage test.
STE/ICE-R #89.
If wire 1276 is loose, faulty, or
shorted to ground, gage will not
operate.
3.
Repair wire 1435 (see
schematic Fig 2-26)
or notify DS
Maintenance.
Verify repair, go to
Step 7 of this Fault.
YES
NO
Wipers operate indicating
10 to 14 vdc to circuit breakers
CB10 and CB8.
Circuit breakers CB8 and CB10
not tripped.
Gage wire 1276 OK.
Wire 1435 faulty.
Sending wire faulty.
Gage faulty.
Sending unit faulty.
Dash lock up circuit breaker
CB8 faulty.
Wire 1276 faulty.
KNOWN INFO
POSSIBLE PROBLEMS
TEST OPTIONS
REASON FOR QUESTION
Continuity test.
STE/ICE-R #91.
If gage is not grounded through
wire 1435, gage will not operate.
WARNING
Are 10 to 14 vdc measured on
wire 1276 of suspect gage,
terminal I?
Is wire 1435 at suspect gage,
terminal G grounded?
Read WARNING
on Page 2-1181
|