TM 9-2320-364-20-2 2-1204 7.  INSTRUMENT LIGHTS DO NOT OPERATE. INITIAL SETUP 1. Repair wire 1276 (see schematic Fig 2-28) or notify DS Maintenance.   Verify repair, go to Step 3 of this Fault. START YES NO Instruments operate, indicating   10 to 14 vdc are present at   wires 1276 splice to rheostat. Wire 1276 faulty. Thumbwheel rheostat switch   faulty. KNOWN INFO POSSIBLE PROBLEMS TEST OPTIONS REASON FOR QUESTION Voltage test. STE/ICE-R #89. If wire 1276 is faulty, lamp will not light. 2-20.  ELECTRICAL SYSTEM TROUBLESHOOTING (CONT). Tools and Special Tools Tool Kit, General Mechanic’s:  Automotive (Item 74, Appendix G) STE/ICE-R (optional) (Item 3, Appendix G) Multimeter (Item 44, Appendix G) Equipment Condition Engine OFF, (TM 9-2320-364-10) Parking brake applied, (TM 9-2320-364-10) Wheels chocked, (TM 9-2320-364-10) References TM 9-2320-364-10 TM 9-4910-571-12&P Are 10 to 14 vdc measured on wire 1276 at thumbwheel rheostat switch? WARNING Read   WARNING on Page 2-1205

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business