TM 9-2320-364-20-2
2-1305
(1) Set multimeter select switch to ohms.
(2) Is there continuity between turn signal
socket ground contact and a known
good ground?
(a) If there is no continuity, replace
right front composite light
(Para 7-46).
(b) If there is continuity, fault not
corrected. Notify DS
Maintenance.
(3) Install turn light lamp.
(4) Install preformed packing, composite
light cover and tighten five screws.
CONTINUITY TEST
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive electrical
circuits, a direct short may result. Damage to equipment, injury or death to personnel may occur.
|