TM 9-2320-364-20-2
2-1321
(1) Connect positive (+) multimeter lead
to wire 1009 at front brake pressure
switch.
(2) Connect negative () multimeter lead
to a known good ground.
(3) While assistant applies brake pedal
(TM 9-2320-364-10), observe
multimeter.
(a) If 10 to 14 vdc are not present,
release brake pedal and repair
wire 1009 (see schematic
Fig 2-32) or notify DS
Maintenance.
(b) If 10 to 14 vdc are present,
wire 1009 is OK.
(4) Release brake pedal.
VOLTAGE TEST
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive electrical
circuits, a direct short may result. Damage to equipment, injury or death to personnel may occur.
|