TM 9-2320-364-20-2
2-1508
38. TRANS CHECK LIGHT WILL NOT OPERATE (CONT).
Gages work indicating 10 to 14
vdc present on wire 1276.
TRANS CHECK light lamp OK.
Wire 1276 OK.
Relay R9 wire 1435 OK.
Wire 1435 OK.
TRANS CHECK relay R9
faulty.
Wire 1409 faulty.
KNOWN INFO
POSSIBLE PROBLEMS
TEST OPTIONS
REASON FOR QUESTION
Continuity test.
STE/ICE-R #91.
If continuity is not measured,
TRANS CHECK relay R9
is faulty.
YES
NO
Replace TRANS
CHECK relay
(Para 7-95).
Verify repair, go to
Step 6 of this Fault.
5.
Is continuity measured on wire
1409 between CK TRANS
relay R9, terminal 30 and a
known good ground?
Repair wire 1409
(see schematic
Fig 2-41) or notify
DS Maintenance.
Verify repair, go to
Step 6 of this Fault.
4.
Repair wire 1435
(see schematic
Fig. 2-41) or notify
DS Maintenance.
Verify repair, go to
Step 6 of this Fault.
YES
NO
Gages work indicating 10 to 14
vdc present on wire 1276.
TRANS CHECK light lamp OK.
Wire 1276 OK.
Wire 1435 faulty.
TRANS CHECK relay R9
faulty.
Wire 1409 faulty.
KNOWN INFO
POSSIBLE PROBLEMS
TEST OPTIONS
REASON FOR QUESTION
Continuity test.
STE/ICE-R #91.
If relay R9 is not grounded
through wire 1435, TRANS
CHECK light will not operate.
WARNING
WARNING
Is continuity measured on
wire 1435 between TRANS
CHECK relay R9, terminal 87A
and a known good ground?
Read WARNING
on Page 2-1509
Read WARNING
on Page 2-1509
|