TM 9-2320-364-20-2
2-1585
(1) Bleed air system pressure until green
and red needles in gage are below 60
psi (414 kPa) (TM 9-2320-364-10).
(2) Turn ON ENGINE switch.
(a) If LOW AIR light and LOW
AIR/HYDRAULIC OIL alarm do
not operate, fault not corrected.
Notify DS Maintenance.
(b) If LOW AIR and LOW
AIR/HYDRAULIC OIL alarm
operate, fault corrected.
(3) Turn OFF ENGINE switch.
VERIFY REPAIR
NOTE
Do not perform Step (1) below if air pressure
gage indicates less than 60 psi (414 kPa).
|