TM 9-2320-364-20-2
2-1658
54. 12 AND 24 VOLT SYSTEMS NOT CHARGING OR UNDER CHARGING
(200 AMP) (CONT).
KNOWN INFO
POSSIBLE PROBLEMS
TEST OPTIONS
REASON FOR QUESTION
Voltage test.
STE/ICE-R #89.
Islolate fault.
YES
NO
Replace alternator
(Para 7-3). Verify
repair, go to Step 9 of
this Fault.
6.
Is alternator functioning
properly?
Replace voltage
regulator (Para 7-8).
Verify repair, go to
Step 9 of this Fault.
WARNING
Read WARNING
on Page 2-1659
Both voltmeters indicate low
charge.
Batteries OK.
Fuel pump operates indicating
24 vdc present at CB24.
Alternator belts OK.
Fusible link loop OK.
Wire 1275 OK.
Wire 1020A OK.
Oil pressure switch OK.
Wire 1020B OK.
Alternator faulty.
Voltage regulator faulty.
|