TM 9-2320-364-20-2
2-1672
56. 24 VOLT SYSTEM OVER OR UNDER CHARGING (200 AMP) (CONT).
24 vdc voltmeter indicates low
charge.
12 vdc voltmeter indicates
proper charge.
Batteries OK.
24 vdc voltmeter OK.
Voltage regulator OK.
KNOWN INFO
POSSIBLE PROBLEMS
TEST OPTIONS
REASON FOR QUESTION
Verify repair.
If 24 vdc voltmeter indicates
proper voltage, fault corrected.
YES
NO
Fault not corrected.
Notify Supervisor.
2.
Is the 24 vdc charging system
charging properly?
Fault corrected.
|