TM 9-2320-364-20-2
2-1725/(2-1726 blank)
(1) Set multimeter select switch to ohms.
(2) Turn on TRANSFER CASE LOCKUP
switch (TM 9-2320-364-10).
(3) Is there continuity between transfer case
lockup switch, terminals 1 and 5.
(a) If there is no continuity,
perform Steps (4) and (5) below
and replace transfer case
lockup switch (Para 7-30).
(b) If there is continuity, repair wire
1883 (see schematic Fig 2-42) or
notify DS Maintenance.
(4) Connect transfer case lockup
switch to harness connector.
(5) Install ECB side panel and six screws.
CONTINUITY TEST
(1) Turn ON ENGINE switch
(TM 9-2320-364-10).
(2) Turn on TRANSFER CASE LOCKUP
switch.
(a) If transfer case does not lockup,
fault not corrected. Perform
Steps (3) and (4) below and notify
Supervisor.
(b) If transfer case does lockup, fault
has been corrected.
(3) Turn off TRANSFER CASE LOCKUP
switch.
(4) Turn OFF ENGINE switch.
VERIFY REPAIR
|