TM 9-2320-364-20-3
2-2881
(1) Set multimeter select switch to ohms.
(2) Set WINCH/CRANE switch to CRANE
position (TM 9-2320-364-10).
(3) Is there continuity between
WINCH/CRANE switch, terminals 1
and 5?
(a) If there is no continuity,
replace switch (Para 17-20).
(b) If there is continuity, go to Step (4)
below.
(4) Set WINCH/CRANE switch to WINCH
position.
(5) Is there continuity between
WINCH/CRANE switch, terminals 5
and 7?
(a) If there is no continuity, replace
switch (Para 17-20).
(b) If there is continuity, switch is OK.
(6) Connect connector to WINCH/CRANE
switch.
(7) Install ECB side panel with six screws.
CONTINUITY TEST
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive electrical
circuits, a direct short may result. Damage to equipment, injury or death to personnel may occur.
|