TM 9-2320-364-20-3
2-2887
(1) Set multimeter select switch to ohms.
(2) Is there continuity on wire 1435
between connector MC83, terminal F
and a known good ground?
(a) If there is no continuity, repair
wire 1435 (see schematic
Fig 2-52) or notify DS
Maintenance.
(b) If there is continuity, wire 1435
is OK.
CONTINUITY TEST
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive electrical
circuits, a direct short may result. Damage to equipment, injury or death to personnel may occur.
|