TM 9-2320-364-20-3 2-2902 4.  FAN, LHS, WINCH AND CRANE DO NOT OPERATE (CONT). Truck hoses OK. Crane hoses and tubes OK. Hydraulic oil level OK. Pump driveshaft OK. High pressure filter OK. Strainer OK. Main hydraulic filter OK. KNOWN INFO POSSIBLE PROBLEMS TEST OPTIONS REASON FOR QUESTION Verify repair. If fan, LHS, winch and crane operate, fault has been corrected. YES NO Fault not corrected, notify DS Maintenance. 7. Do fan, LHS, winch and crane operate normally? Fault corrected. 6. Replace main hydraulic filter and clean or replace relief valve (Para 20-9). Verify repair, go to Step 7 of this Fault. YES NO Truck hoses OK. Crane hoses and tubes OK. Hydraulic oil level OK. Pump driveshaft OK. High pressure filter OK. Strainer OK. Main hydraulic filter clogged. KNOWN INFO POSSIBLE PROBLEMS TEST OPTIONS REASON FOR QUESTION Visual inspection. Clogged return filter and relief valve will not allow pressure to return to hydraulic reservoir. Are main hydraulic filter and relief valve free of restrictions?

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business