TM 9-2320-364-20-3
2-2923
(1) Disconnect connector MC128 from
temperature switch.
(2) Is there continuity between
temperature switch terminals A and B?
(a) If there is no continuity, replace
temperature switch (Para 7-80).
(b) If there is continuity, notify DS
Maintenance. Perform Steps (3)
and (4) below.
(3) Connect connector MC128 to
temperature switch.
(4) Install engine access panel with 22
screws, lockwashers and washers.
CONTINUITY TEST
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive electrical
circuits, a direct short may result. Damage to equipment, injury or death to personnel may occur.
|