TM 9-2320-364-20-3
2-2027
(1) Inspect CTIS controller, front and rear
manifolds to ensure that all connectors
are fully plugged in.
(a) If connectors are not plugged in,
secure connectors.
(b) If connectors are plugged in, go to
Step 2 of this Fault.
(2) Close front access cover
(TM 9-2320-364-10).
VISUAL INSPECTION
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive electrical
circuits, a direct short may result. Damage to equipment, injury or death to personnel may occur.
NOTE
The CTIS initially and periodically checks
for system air leaks. The CTIS controller
will display flashing LOW AIR light and
shut off if 6 psi (41 kPa) cannot be
maintained by the CTIS. The manifold will
click during this check for approximately
1-1/2 minutes.
|