TM 9-2320-364-20-3
2-2082
10. FRONT MANIFOLD CLICKS CONTINUALLY/LOW AIR LIGHT FLASHING (CONT).
19.
Is the quick release valve
operating properly?
Repair or replace
quick release valve
(Para 13-10). Verify
repair, go to Step 28 of
this Fault.
NO
System air pressure greater
than 110 psi (758 kPa).
Rear manifold not clicking
continually.
CTIS harness connections
OK.
CTIS controller OK.
CTIS wire harness OK.
Air line 2993 and fittings OK.
CTIS front manifold not
leaking.
CTIS hub seals OK.
Front manifold deflate valve
OK.
KNOWN INFO
POSSIBLE PROBLEMS
TEST OPTIONS
REASON FOR QUESTION
Visual inspection.
Quick release valve which
remains in the open position or
leaks will cause CTIS to turn
off and LOW AIR light will flash.
Front manifold quick release
valve faulty.
CTIS front manifold faulty.
YES
|