TM 9-2320-364-20-3
2-2088
10. FRONT MANIFOLD CLICKS CONTINUALLY/LOW AIR LIGHT FLASHING (CONT).
22.
Is there continuity measured
between terminal 1 of quick
release valve connector and
ground?
Replace front manifold
(Para 13-8). Verify
repair, go to Step 28 of
this Fault.
YES
NO
System air pressure greater
than 110 psi (758 kPa).
Rear manifold not clicking
continually.
CTIS wire harness
connections OK.
CTIS controller OK.
CTIS wire harness OK.
Air line 2993 and fittings OK.
CTIS front manifold not
leaking.
Quick release valve OK.
Quick release valve solenoid
OK.
24 vdc input to quick release
valve.
KNOWN INFO
POSSIBLE PROBLEMS
TEST OPTIONS
REASON FOR QUESTION
Continuity test.
STE/ICE-R#91.
If no continuity is measured,
front manifold is faulty.
CTIS front manifold faulty.
|