10. FRONT MANIFOLD CLICKS CONTINUALLY/LOW AIR LIGHT FLASHING (CONT).
24.
Are 10 to 14 vdc (pulsating)
measured at inflate valve
connector, terminal 2?
Replace front manifold
(Para 13-8). Verify
repair, go to Step 28 of
this Fault.
YES
NO
System air pressure greater
than 110 psi (758 kPa).
Rear manifold not clicking
continually.
CTIS wire harness
connections OK.
CTIS controller OK.
CTIS wire harness OK.
Air line 2993 and fittings OK.
CTIS front manifold not
leaking.
No air pressure at transducer.
KNOWN INFO
POSSIBLE PROBLEMS
TEST OPTIONS
REASON FOR QUESTION
Voltage test.
STE/ICE-R#89.
If no voltage is present, front
manifold is faulty.
WARNING
CTIS front manifold faulty.
Inflate valve solenoid faulty.
Inflate valve faulty.
Read WARNING
on Page 2-2093
|