Page Title: 10. FRONT MANIFOLD CLICKS CONTINUALLY/LOW AIR LIGHT FLASHING (CONT)
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

TM 9-2320-364-20-3 2-2098 10.  FRONT MANIFOLD CLICKS CONTINUALLY/LOW AIR LIGHT FLASHING (CONT). 27. Is the inflate valve operating properly? Replace inflate valve (Para 13-10).  Verify repair, go to Step 28 of this Fault. YES NO System air pressure greater   than 110 psi (758 kPa). Rear manifold not clicking   continually. CTIS wire harness   connections OK. CTIS controller OK. CTIS wire harness OK. Air line 2993 and fittings OK. CTIS front manifold not   leaking. CTIS front manifold OK. No air pressure at transducer. 10 to 14 vdc present at inflate   valve connector. Inflate valve solenoid OK. KNOWN INFO POSSIBLE PROBLEMS TEST OPTIONS REASON FOR QUESTION Visual inspection. Inflate valve which remains closed will not allow inflation. Inflate valve faulty. Fault not corrected.  Notify Supervisor.