TM 9-2320-364-20-3
2-2098
10. FRONT MANIFOLD CLICKS CONTINUALLY/LOW AIR LIGHT FLASHING (CONT).
27.
Is the inflate valve operating
properly?
Replace inflate valve
(Para 13-10). Verify
repair, go to Step 28 of
this Fault.
YES
NO
System air pressure greater
than 110 psi (758 kPa).
Rear manifold not clicking
continually.
CTIS wire harness
connections OK.
CTIS controller OK.
CTIS wire harness OK.
Air line 2993 and fittings OK.
CTIS front manifold not
leaking.
CTIS front manifold OK.
No air pressure at transducer.
10 to 14 vdc present at inflate
valve connector.
Inflate valve solenoid OK.
KNOWN INFO
POSSIBLE PROBLEMS
TEST OPTIONS
REASON FOR QUESTION
Visual inspection.
Inflate valve which remains
closed will not allow inflation.
Inflate valve faulty.
Fault not
corrected. Notify
Supervisor.
|