11. REAR MANIFOLD CLICKS CONTINUALLY/LOW AIR LIGHT FLASHING (CONT).
19.
Is the quick release valve
operating properly?
Repair or replace
quick release valve
(Para 13-10). Verify
repair, go to Step 28 of
the Fault.
YES
NO
System air pressure greater
than 110 psi (758 kPa).
Front manifold not clicking
continually.
CTIS harness connections OK.
CTIS controller OK.
CTIS wire harness OK.
Air line 2994 and fittings OK.
CTIS rear manifold not
damaged or leaking.
Rear manifold deflate valve
OK.
Rear manifold deflate valve
faulty.
Rear manifold quick release
valve faulty.
Rear manifold faulty.
KNOWN INFO
POSSIBLE PROBLEMS
TEST OPTIONS
REASON FOR QUESTION
Visual inspection.
Quick release valve which
remains in the open position or
leaks will cause CTIS to turn
off and LOW AIR light will flash.
|