Page Title: 13. CTIS LOW AIR INDICATOR STAYS ON OVER 110 PSI (CONT)
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

TM 9-2320-364-20-3 2-2172    13.  CTIS LOW AIR INDICATOR STAYS ON OVER 110 PSI (CONT). 3. Is continuity measured on all wires between connector MC 111 and connector MC 109? Repair wires (see schematic Fig 2-48) or notify DS Maintenance.  Verify repair, go to Step 6 of this Fault. YES NO System air pressure greater   than 110 psi (758 kPa). LOW AIR light solid. Pressure switch OK. KNOWN INFO POSSIBLE PROBLEMS TEST OPTIONS REASON FOR QUESTION Continuity test. STE/ICE-R #91. If wire harness is faulty LOW AIR light will come on. WARNING CTIS wire harness faulty. CTIS controller faulty. Front manifold faulty. Read   WARNING on Page 2-2173