TM 9-2320-364-20-3 2-2204 3.  COMPRESSOR FAILS TO UNLOAD (AIR SYSTEM PRESSURE BUILDS UP TO MORE THAN 129 PSI (889 KPA)). INITIAL SETUP 1. Is air line 2159 free of damage, crimps or leaks and are fittings free of leaks? Tighten loose fittings or replace air line 2159 (Para 12-36 and schematic Fig 2-50). Verify repair, go to Step 3 of this Fault. START YES NO Nothing. Leaking air governor control   air line. Air governor faulty. KNOWN INFO POSSIBLE PROBLEMS TEST OPTIONS REASON FOR QUESTION Visual inspection. Audible inspection. Compressor will fail to unload if governor control air line 2159 is leaking or damaged. 2-27.  AIR SYSTEM TROUBLESHOOTING (CONT). Tools and Special Tools Tool Kit, General Mechanic’s:  Automotive (Item 74, Appendix G) Equipment Condition Engine OFF, (TM 9-2320-364-10) Parking brakes applied, (TM 9-2320-364-10) Wheels chocked, (TM 9-2320-364-10) Right side noise panel removed, (Para 17-26) References TM 9-2320-364-10 WARNING Personnel Required Two NOTE Soap and water solution will be used to visually check for leaks. Materials/Parts Solution, Soap (Item 86, Appendix C) Read   WARNING on Page 2-2205

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business