TM 9-2320-364-20-3
2-2243
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive electrical
circuits, a direct short may result. Damage to equipment, injury or death to personnel may occur.
(1) Set multimeter select switch to ohms.
(2) Is there continuity between harness
connector MC83, terminal F and a
known good ground?
(a) If there is no continuity, repair wire
1435 (see schematic Fig 2-52) or
notify DS Maintenance.
(b) If there is continuity, wire 1435
is OK.
CONTINUITY TEST
|