TM 9-2320-364-20-3
2-2245
(1) Remove six screws and tilt ECB side
panel.
(2) Disconnect harness connector MC94.
(3) Is there continuity between harness
connector MC83, terminal M and
harness connector MC94, terminal D?
(a) If there is no continuity, repair wire
1488 (see schematic Fig 2-52)
and perform Step (4) below or
notify DS Maintenance).
(b) If there is continuity, wire 1488
is OK.
(4) Install LHS control assy (Para 7-40).
CONTINUITY TEST
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive electrical
circuits, a direct short may result. Damage to equipment, injury or death to personnel may occur.
|