(1) Disconnect harness connector MC93
from switch connector.
(2) Set hydraulic selector switch to
MAN HA position
(TM 9-2320-364-10).
(3) Set multimeter select switch to ohms.
(4) Is there continuity between harness
connector MC93, terminal E and
harness connector MC94, terminal D?
(a) If there is no continuity, replace
hydraulic selector switch
(Para 7-31) and perform Steps
(7) and (8) below.
(b) If there is continuity, perform
Step (5) below.
(5) Set hydraulic selector switch to
MAN MF and repeat Step (4) above.
If there is continuity, perform
Step (6) below.
(6) Set hydraulic selector switch to AUTO
and repeat Step (4) above. If
there is continuity, hydraulic selector
switch is OK and perform Steps (7) and
(8) below.
(7) Set hydraulic selector switch to OFF
position.
(8) Connect harness connector MC94 to
switch connector.
CONTINUITY TEST
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive electrical
circuits, a direct short may result. Damage to equipment, injury or death to personnel may occur.
|