TM 9-2320-364-20-3
2-2251
(1) Remove LHS control assy
(Para 7-40).
(2) Set multimeter select switch to ohms.
(3) Is there continuity between harness
connector MC83, terminal G and
harness connector MC93, terminal E?
(a) If there is no continuity, repair wire
1483 (see schematic Fig 2-52)
and perform Steps (4) and (5)
below or notify DS Maintenance.
(b) If there is continuity, wire 1483
is OK.
(4) Connect harness connector MC93.
(5) Install ECB side panel and six screws.
CONTINUITY TEST
Remove all jewelry such as rings, dog tags,
bracelets, etc. If jewelry or tools contact positive
electrical circuits, a direct short may result.
Damage to equipment, injury or death to
personnel may occur.
|