TM 9-2320-364-20-3
2-2321
(1) Set multimeter select switch to ohms.
(2) Is there continuity between transit
valve harness connector terminal 1
and a known good ground?
(a) If there is no continuity, repair wire
1435 (see schematic Fig 2-52) or
notify DS Maintenance.
(b) If there is continuity, wire 1435
is OK. Notify DS Maintenance.
(3) Install connector on transit valve and
tighten connector screw, coat head of
connector screw with adhesive.
CONTINUITY TEST
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive electrical
circuits, a direct short may result. Damage to equipment, injury or death to personnel may occur.
Adhesive, solvents, and sealing compounds can burn easily, can give off harmful vapors, and are
harmful to skin and clothing. To avoid injury or death, keep away from open fire and use in a
well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash
immediately with soap and water.
|