TM 9-2320-364-20-3
2-2329
Keep clear of equipment when equipment
is being raised or lowered. Equipment
may fall and cause serious injury or
death to personnel.
Remove all jewelry such as rings, dog
tags, bracelets, etc. If jewelry or
tools contact positive electrical circuits,
a direct short may result. Damage to
equipment, injury or death to personnel
may occur.
Never crawl under equipment when performing
maintenance unless equipment is securely
blocked. Equipment may fall and cause
serious injury or death to personnel.
Do not work on any item supported only
by lift jacks or hoist. Always use blocks
or proper stands to support the item prior
to any work. Equipment may fall and cause
injury or death to personnel.
Adhesive, solvents, and sealing compounds
can burn easily, can give off harmful vapors,
and are harmful to skin and clothing. To
avoid injury or death, keep away from open
fire and use in a well-ventilated area. If
adhesive, solvent, or sealing compound gets
on skin or clothing, wash immediately with
soap and water.
(12) Tighten screw and coat head of
connector screw with adhesive.
(13) Loosen screw and disconnect
connector from the remaining safe
lowering valve on the LH side
of the LHS.
(14) Is there continuity between
remaining left side lowering valve
harness connector terminal 2 and a
known good ground?
(a) If there is no continuity, repair
wire 1470 (see schematic
Fig 2-52) or notify DS
Maintenance.
(b) If there is continuity, perform
Steps (15) and (16) below.
(15) Connect connector to safe lowering
valve.
(16) Tighten connector screw and coat
head of connector screw with
adhesive.
CONTINUITY TEST (cont).
|