TM 9-2320-364-20-3
2-1926
2. CTIS INOPERATIVE (CONT).
2.
Replace circuit
breaker (Para 7-16).
Verify repair, go to
Step 11 of this Fault.
YES
NO
Heater operates indicating 24
vdc are input to circuit breaker
CB17.
System air pressure greater
than 110 psi (758 kPa).
CTIS lines and components
not leaking.
No lights illuminated on
controller.
CTIS wire harness connections
OK.
Voltage regulator faulty.
CTIS protection device faulty.
Circuit breaker CB17 faulty.
Wire 1880 faulty.
Wire 1435 faulty.
CTIS controller faulty.
Wire 1065 faulty.
Front manifold faulty.
Wire 1064 faulty.
KNOWN INFO
POSSIBLE PROBLEMS
TEST OPTIONS
REASON FOR QUESTION
Voltage test.
STE/ICE-R #89.
If 22 to 28 vdc are not present
at wire 1880, circuit breaker
CB17 is faulty.
WARNING
3.
Voltage Regulator
faulty (Para 7-6)
or
(Para 7-8).
YES
NO
Heater operates indicating 24
vdc are input to circuit breaker
CB17.
System air pressure greater
than 110 psi (758 kPa).
CTIS lines and components
not leaking.
No lights illuminated on
controller.
CTIS wire harness connections
OK.
Voltage regulator faulty.
CTIS protection device faulty.
Circuit breaker CB17 faulty.
Wire 1880 faulty.
Wire 1435 faulty.
CTIS controller faulty.
Wire 1065 faulty.
Front manifold faulty.
Wire 1064 faulty.
KNOWN INFO
POSSIBLE PROBLEMS
TEST OPTIONS
REASON FOR QUESTION
Voltage test.
STE/ICE-R #89.
If more than 30 vdc are
present at wire 1880, voltage
regulator is faulty.
Are 22 to 28 vdc measured on
wire 1880 at circuit breaker
CB17?
Is less than 30 vdc measured
on wire 1880 at circuit breaker
CB17?
Read WARNING
on Page 2-1927
|