TM 9-2320-364-20-3 2-2376 9.  HOOK ARM DOES NOT UNLOAD IN MANUAL MODE (CONT). 8. Repair wire 1464 (see schematic Fig 2-52) or notify DS Maintenance. Verify repair, go to Step 10 of this Fault. YES NO LHS hoses OK. LHS tubes OK. Wire 1489 OK. Wire 1482 OK. Hydraulic selector switch OK. LHS control assembly OK. Wire 1464 faulty. Wire 1435 faulty. KNOWN INFO POSSIBLE PROBLEMS TEST OPTIONS REASON FOR QUESTION Continuity test. STE/ICE-R #91. If wire 1464 is faulty, 22 to 28 vdc will not be present at hook arm up DC valve. WARNING Is continuity measured on wire 1464 at hook arm up DC valve harness connector, terminal 2 and harness connector MC81, terminal D? Read   WARNING on Page 2-2377