TM 9-2320-364-20-3
2-1928
2. CTIS INOPERATIVE (CONT).
4.
Replace controller
protection
device (Para 13-13).
Verify repair, go to
Step 11 of this Fault.
YES
NO
Heater operates indicating 24
vdc are input to circuit breaker
CB17.
System air pressure greater
than 110 psi (758 kPa).
CTIS lines and components
not leaking.
No lights illuminated on
controller.
CTIS wire harness connections
OK.
Voltage regulator OK.
Circuit breaker CB17 OK.
CTIS protection device faulty.
Wire 1880 faulty.
Wire 1435 faulty.
CTIS controller faulty.
Wire 1065 faulty.
Front manifold faulty.
Wire 1064 faulty.
KNOWN INFO
POSSIBLE PROBLEMS
TEST OPTIONS
REASON FOR QUESTION
Voltage test.
STE/ICE-R #89.
If 22 to 28 vdc are not present,
protection device is faulty.
WARNING
5.
Repair wire 1880
(see schematic
Fig 2-48) or notify
DS Maintenance.
Verify repair, go to
Step 11 of this Fault.
YES
NO
Heater operates indicating 24
vdc are input to circuit breaker
CB17.
System air pressure greater
than 110 psi (758 kPa).
CTIS lines and components
not leaking.
No lights illuminated on
controller.
CTIS wire harness connections
OK.
Voltage regulator OK.
CTIS protection device OK.
Circuit breaker CB17 OK.
Wire 1880 faulty.
Wire 1435 faulty.
CTIS controller faulty.
Wire 1065 faulty.
Front manifold faulty.
Wire 1064 faulty.
KNOWN INFO
POSSIBLE PROBLEMS
TEST OPTIONS
REASON FOR QUESTION
Voltage test.
STE/ICE-R #89.
If 22 to 28 vdc are not present,
wire 1880 is faulty.
Are 22 to 28 vdc measured on
wire 1880 at protection device
connector MC35 terminal 10?
Are 22 to 28 vdc measured on
wire 1880 at harness
connector MC35, terminal 10?
Read WARNING
on Page 2-1929
WARNING
Read WARNING
on Page 2-1929
|