2. CTIS INOPERATIVE (CONT).
7.
Replace CTIS
controller (Para 13-7).
Verify repair, go to
Step 11 of this Fault.
YES
NO
Heater operates indicating 24
vdc are input to circuit breaker
CB17.
System air pressure is greater
than 110 psi (758 kPa).
CTIS lines and components
not leaking.
No lights illuminated on
controller.
CTIS wire harness connections
OK.
Voltage regulator OK.
CTIS protection device OK.
Circuit breaker CB17 OK.
Wire 1880 OK.
Wire 1435 OK.
CTIS controller faulty.
Wire 1065 faulty.
Front manifold faulty.
Wire 1064 faulty.
KNOWN INFO
POSSIBLE PROBLEMS
TEST OPTIONS
REASON FOR QUESTION
Voltage test.
STE/ICE-R #89.
If 22 to 28 vdc are not present
at CTIS controller connector
MC111, terminal 10, CTIS
controller is faulty.
WARNING
8.
Are 22 to 28 vdc measured on
wire 1065 at connector
MC109, terminal 10?
Repair wire 1065
(see schematic
Fig 2-48) or notify
DS Maintenance.
Verify repair, go to
Step 11 of this Fault.
YES
NO
Heater operates indicating 24
vdc are input to circuit breaker
CB17.
System air pressure greater
than 110 psi (758 kPa).
CTIS lines and components
not leaking.
No lights illuminated on
controller.
CTIS wire harness connections
OK.
Voltage regulator OK.
CTIS protection device OK.
Circuit breaker CB17 OK.
Wire 1880 OK.
Wire 1435 OK.
CTIS controller OK.
Wire 1065 faulty.
Front manifold faulty.
Wire 1064 faulty.
KNOWN INFO
POSSIBLE PROBLEMS
TEST OPTIONS
REASON FOR QUESTION
Voltage test.
STE/ICE-R #89.
If 22 to 28 vdc are not present at
connector MC109, terminal 10,
wire 1065 is faulty.
Are 22 to 28 vdc measured at
CTIS controller connector
MC111, terminal 10?
WARNING
Read WARNING
on Page 2-1933
Read WARNING
on Page 2-1933
|