TM 9-2320-364-20-3
2-2435
(1) Disconnect LHS control assembly
from connectors.
(2) Set multimeter selector switch to
ohms.
(3) Is there continuity between middle
frame down DC valve harness
connector, terminal 2 and harness
connector MC81, terminal C?
(a) If there is no continuity, repair wire
1468 (see schematic Fig 2-52) or
notify DS Maintenance.
(b) If there is continuity, wire 1468 is
OK.
(4) Install LHS control assembly
(Para 7-40).
CONTINUITY TEST
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive electrical