TM 9-2320-364-20-3
2-1934
2. CTIS INOPERATIVE (CONT).
Heater operates indicating 24
vdc are input to circuit breaker
CB17.
System air pressure is greater
than 110 psi (758 kPa).
CTIS lines and components
not leaking.
No lights illuminated on
controller.
CTIS wire harness connections
OK.
Voltage regulator OK.
CTIS protection device OK.
Circuit breaker CB17 OK.
Wire 1880 OK.
Wire 1065 OK.
Wire 1435 OK.
CTIS controller OK.
Wire 1065 OK.
Front manifold OK.
Wire 1064 faulty.
KNOWN INFO
POSSIBLE PROBLEMS
TEST OPTIONS
REASON FOR QUESTION
Continuity test.
STE/ICE-R #91.
If there is no continuity, wire 1064
is faulty. If there is continuity,
CTIS controller is faulty.
NO
Repair wire 1064
(see schematic
Fig 2-48) or notify
DS Maintenance.
Verify repair, go to
Step 11 of this Fault.
10.
Is continuity measured on
wire 1064 between harness
connector MC109 and harness
connector MC111?
Replace CTIS
controller (Para 13-7).
Verify repair, go to
Step 9 of this Fault.
9.
YES
NO
Heater operates indicating 24
vdc are input to circuit breaker
CB17.
System air pressure is greater
than 110 psi (758 kPa).
CTIS lines and components
not leaking.
No lights illuminated on
controller.
CTIS wire harness connections
OK.
Votlage regulator OK.
CTIS protection device OK.
Circuit breaker CB17 OK.
Wire 1880 OK.
Wire 1435 OK.
CTIS controller OK.
Wire 1065 OK.
Front manifold faulty.
Wire 1064 faulty.
KNOWN INFO
POSSIBLE PROBLEMS
TEST OPTIONS
REASON FOR QUESTION
Voltage test.
STE/ICE-R #89.
If 13-14 vdc are not present at
front manifold connector MC109,
terminal 9, front manifold is
faulty.
WARNING
Are 13-14 vdc measured at
back of connector MC109,
terminal 9 with MC109
connected to front manifold?
Replace front manifold
(Para 13-8).
Verify repair, go to
Step 11 of this Fault.
YES
Read WARNING
on Page 2-1935
|