TM 9-2320-364-20-3
2-2482
5.
Repair wire 1435 (see
schematic Fig 2-56) or
notify DS Mainte-
nance. Verify repair,
go to Step 18 of this
Fault.
YES
NO
No mission module hooked up
to interface quick disconnect.
LED #2 lamp is ON.
Wire 1790 from LED #2 lamp to
connector MC135 terminal D
OK.
Wire 1790 from connector
MC135 terminal D to connector
MC133 terminal 1 OK.
Wire 1435 between connector
MC133 terminal 2 and
connector MC135 terminal E
OK.
Wire 1435 between connector
MC135 terminal E and LED
#2 lamp faulty.
KNOWN INFO
POSSIBLE PROBLEMS
TEST OPTIONS
REASON FOR QUESTION
Continuity test.
STE/ICE-R #91.
LHS will not work if wire 1435 is
not grounded.
Is continuity measured on
wire 1435 between LED #2
lamp and connector MC135
terminal E?
15 LHS INOPERATIVE WITH INTERFACE KIT INSTALLED (CONT).
WARNING
Read WARNING
on Page 2-2483
Go to Step 18
of this Fault.
|