TM 9-2320-364-20-3
2-2522
1. NO CRANE FUNCTIONS WORK USING REMOTE CONTROL (CONT).
4.
Repair wire 4
(see schematic
Fig 2-58) or notify
DS Maintenance.
Verify repair, go to
Step 8 of this Fault.
YES
NO
All crane functions operate
using controls mounted on
crane.
Violet wire from terminal 8 to
remote control connector outlet
terminal H OK.
Green wire from remote control
connector, terminal B to crane
junction box ground OK.
Remote control unit cable is OK.
Remote control unit wire 4
faulty.
ON/OFF EMERGENCY STOP
switch faulty.
Remote control unit wire 8 from
ON/OFF switch to four terminal
connector faulty.
Remote control unit wire 2
faulty.
KNOWN INFO
POSSIBLE PROBLEMS
TEST OPTIONS
REASON FOR QUESTION
Voltage test.
STE/ICE-R #89.
If wire 4 from remote control unit
hookup terminal H to ON/OFF
EMERGENCY STOP switch
faulty, 22 to 28 vdc will not be
present at controller.
WARNING
5.
Replace switch
(Para 18-4).
Verify repair, go to
Step 8 of this Fault.
YES
NO
All crane functions operate
using controls mounted on
crane.
Violet wire from terminal 8 to
remote control connector outlet
terminal H OK.
Green wire from remote control
connector, terminal B to crane
junction box ground OK.
Remote control unit cable is OK.
Remote control unit wire 4 OK.
ON/OFF EMERGENCY STOP
switch faulty.
Remote control unit wire 8 from
ON/OFF switch to four terminal
connector faulty.
Remote control unit wire 2
faulty.
KNOWN INFO
POSSIBLE PROBLEMS
TEST OPTIONS
REASON FOR QUESTION
Voltage test.
STE/ICE-R #89.
If switch is faulty, 22 to 28 vdc
will not be present at wire 8A.
WARNING
Are 22 to 28 vdc measured at
wire 4 on ON/OFF
EMERGENCY STOP switch?
Are 22 to 28 vdc measured at
wire 8A on ON/OFF
EMERGENCY STOP switch
when switch is turned ON?
Read WARNING
on Page 2-2523
Read WARNING
on Page 2-2523
|