Order this information in Print

Order this information on CD-ROM

Download in PDF Format

     

Click here to make tpub.com your Home Page

Page Title: 1. NO CRANE FUNCTIONS WORK USING REMOTE CONTROL (CONT)
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

TM 9-2320-364-20-3 2-2524 1.  NO CRANE FUNCTIONS WORK USING REMOTE CONTROL (CONT). 6. Repair wire 8 (see schematic Fig 2-58) or notify DS Maintenance. Verify repair, go to Step 8 of this Fault. YES NO All crane functions operate   using controls mounted on   crane. Violet wire from terminal 8 to   remote control connector outlet   terminal H OK. Green wire from remote control   connector, terminal B to crane   junction box ground OK. Remote control unit cable OK. Remote control unit wire 4 OK. ON/OFF EMERGENCY STOP   switch OK. Remote control unit wire 8 from   ON/OFF switch to four terminal   connector faulty. Remote control unit wire 2   faulty. KNOWN INFO POSSIBLE PROBLEMS TEST OPTIONS REASON FOR QUESTION Continuity test. STE/ICE-R #91. If wire 8 is loose, faulty or shorted to ground, 22 to 28 vdc will not be present at controllers through four terminal connector. WARNING 7. Repair wire 2 (see schematic Fig 2-58) or notify DS Maintenance.   Verify repair, go to Step 8 of this Fault YES NO All crane functions operate   using controls mounted on   crane. Violet wire from terminal 8 to   remote control connector outlet   terminal H OK. Green wire from remote control   connector, terminal B to crane   junction box ground OK. Remote control unit cable OK. Remote control unit wire 4 OK. ON/OFF EMERGENCY STOP   switch OK. Remote control unit wire 8 from   ON/OFF switch to four terminal   connector is OK. Remote control unit wire 2   faulty. KNOWN INFO POSSIBLE PROBLEMS TEST OPTIONS REASON FOR QUESTION Continuity test. STE/ICE-R #91. If wire 2 between the four terminal connector and hookup terminal B is loose, faulty or shorted, controller will not be grounded. Is continuity measured on wire 8A between boom four terminal connector and ON/OFF EMERGENCY STOP switch? Is continuity measured between remote control connector, terminal B and wire 2 at boom four terminal connector? Read   WARNING on Page 2-2525 WARNING Read   WARNING on Page 2-2525

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business