TM 9-2320-364-20-3
2-2694
10. OUTRIGGERS DO NOT OPERATE (CONT).
12.
OSS faulty.
Notify DS
Maintenance.
YES
NO
WINCH/CRANE switch in
CRANE position.
Self recovery winch operates.
Hose 2902 OK.
Crane hoses and tubes OK.
Wire 1738 OK.
White wire from truck connector
MC29 to rectifier OK.
Retifier OK.
White wire from rectifier to
POWER switch OK.
POWER switch OK.
Black wire from POWER
switch to OSS OK.
OSS faulty.
Red wire from OSS to crane
junction box, terminal 19
faulty.
Outrigger/mast shutdown
valve harness connector
white wire faulty.
Outrigger/mast shutdown
valve harness connector
black wire faulty.
WINCH/CRANE switch faulty.
Wire 1731 faulty.
Black wire from truck
connector MC29 to system
shutdown relay faulty.
System shutdown relay faulty.
White wire from system
shutdown relay to crane
junction box, terminal 3
faulty.
Main hydraulic pressure valve
harness connector white
wire faulty.
Main hydraulic pressure valve
harness connector black
wire faulty.
KNOWN INFO
POSSIBLE PROBLEMS
TEST OPTIONS
REASON FOR QUESTION
Continuity test.
STE/ICE-R #91.
If OSS is faulty, 22 to 28 vdc will
not be input to outrigger/mast
shutdown valve solenoid.
WARNING
Is continuity measured
between OSS, terminals A
and D?
Read WARNING
on Page 2-2695
|