TM 9-2320-364-20-3
2-2708
10. OUTRIGGERS DO NOT OPERATE (CONT).
19.
Repair black wire (see
schematic Fig 2-58)
or notify DS
Maintenance.
Verify repair, go to
Step 24 of this Fault.
YES
NO
WINCH/CRANE switch in
CRANE position.
Self recovery winch operates.
Hose 2902 OK.
Crane hoses and tubes OK.
Wire 1738 OK.
White wire from truck connector
MC29 to rectifier OK.
Rectifier OK.
White wire from rectifier to
POWER switch OK.
POWER switch OK.
Black wire from POWER
switch to OSS OK.
OSS OK.
Red wire from OSS to crane
junction box, terminal 19 OK.
Outrigger/mast shutdown valve
harness connector white
wire OK.
Outrigger/mast shutdown
valve harness connector
black wire OK.
Outrigger/mast shutdown valve
harness connector black
wire OK.
WINCH/CRANE switch OK.
Wire 1731 OK.
Black wire from truck connector
MC29 to system shutdown
relay faulty.
System shutdown relay faulty.
White wire from system
shutdown relay to crane
junction box, terminal 3
faulty.
Main hydraulic pressure valve
harness connector white
wire faulty.
Main hydraulic pressure valve
harness connector black
wire faulty.
KNOWN INFO
POSSIBLE PROBLEMS
TEST OPTIONS
REASON FOR QUESTION
Voltage test.
STE/ICE-R #89.
If black wire from truck
connector MC29 through crane
junction box terminal 6 to
system shutdown relay is loose,
faulty or shorted to black wire;
22 to 28 vdc will not be input to
main hydraulic pressure valve.
WARNING
Are 22 to 28 vdc measured at
system shutdown relay black
wire with engine switch ON
and hydraulic selector switch
in CRANE/SRW position?
Read WARNING
on Page 2-2709
|