TM 9-2320-364-20-3
2-2723
Inspect accumulator and tube from four
bank valve to accumulator for damage,
crimps or leaks.
(1) If accumulator or tube is leaking,
tighten loose fittings or replace
tube (Para 20-3) or accumulator
(Para 18-10).
(2) If no damage, crimps or leaks are
found, go to Step 3 of this Fault.
VISUAL INSPECTION
High pressure hydraulics [oil under 3,100 psi (21,374 kPa) pressure] operate this equipment. Refer to
vehicle operator and maintenance manuals for hydraulic oil pressure. Never disconnect any hydraulic
line or fittings without first dropping pressure to zero. A high pressure oil stream can pierce body and
cause severe injury to personnel.
|