| |
TM 9-2320-364-20-3
2-2735
(1) Connect positive (+) multimeter lead
to control lockout relay red wire.
(2) Connect negative () multimeter lead
to a known good ground.
(3) Turn ON ENGINE switch
(TM 9-2320-364-10).
(4) Turn on crane POWER switch.
(a) If 22 to 28 vdc are not
present, perform Steps (5) and (6)
below and repair red wire from
crane junction box terminal 5 to
control lockout relay (see
schematic Fig 2-58) or notify DS
Maintenance.
(b) If 22 to 28 vdc are present,
perform Steps (5) and (6) below
and go to Step 10 of this Fault.
(5) Turn off crane POWER switch.
(6) Turn OFF ENGINE switch.
VOLTAGE TEST
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive electrical
circuits, a direct short may result. Damage to equipment, injury or death to personnel may occur.
|