TM 9-2320-364-20-3      2-2737 (1)   Connect positive (+) multimeter lead control lockout relay black wire. (2)   Connect negative (–) multimeter lead to a known good ground. (3)   Turn ON ENGINE switch (TM 9-2320-364-10). (4)   Turn on crane POWER switch. (a)   If 22 to 28 vdc are not present, perform Steps (5) and (6) below and repair black wire from crane junction box terminal 1 to control lockout relay (see schematic Fig 2-58) or notify DS Maintenance. (b)   If 22 to 28 vdc are present, perform Steps (5) and (6) below and go to Step 11 of this Fault. (5)   Turn off crane POWER switch. (6)   Turn OFF ENGINE switch. VOLTAGE TEST Remove all jewelry such as rings, dog tags, bracelets, etc.  If jewelry or tools contact positive electrical circuits, a direct short may result.  Damage to equipment, injury or death to personnel may occur.