TM 9-2320-364-20-3
2-2739
(1) Set multimeter select switch to ohms.
(2) Is there continuity between control
lockout relay green wire and a known
good ground?
(a) If there is no continuity, repair
green wire (see schematic
Fig 2-58) or notify DS
Maintenance.
(b) If there is continuity, wire is OK.
CONTINUITY TEST
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive electrical
circuits, a direct short may result. Damage to equipment, injury or death to personnel may occur.
|