TM 9-2320-364-20-3
2-2747
(1) Is there continuity between system
hydraulic pressure valve connector,
terminal 2 and a known good ground?
(a) If there is no continuity, repair
connector black wire (see
schematic Fig 2-58) or notify DS
Maintenance.
(b) If there is continuity, connector
black wire is OK.
(2) Install junction box cover, six screws
and clips.
CONTINUITY TEST
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive electrical
circuits, a direct short may result. Damage to equipment, injury or death to personnel may occur.
|