TM 9-2320-364-20-3
2-2781
Is there continuity on black wire between
terminal 3 and throttle relay?
(1) If there is no continuity, repair
black wire (see schematic Fig 2-58)
or notify DS Maintenance.
(2) If there is continuity, go to Step 5 of
this Fault.
CONTINUITY TEST
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive electrical
circuits, a direct short may result. Damage to equipment, injury or death to personnel may occur.
|