TM 9-2320-364-20-3
2-2822
1. SRW WILL NOT PAY IN OR OUT USING CONTROL LEVER (CONT).
WINCH/CRANE switch is in
WINCH position.
AUX HYD light L27 operates.
Crane operates.
Hoses 2809, 2899 and 2886 OK.
Control manifold OK.
WINCH/CRANE switch OK.
Wire 1732 OK.
Wire 1435 faulty.
KNOWN INFO
POSSIBLE PROBLEMS
TEST OPTIONS
REASON FOR QUESTION
Continuity test.
STE/ICE-R #91.
If wire 1435 is loose or faulty,
SRW control manifold supply
valve solenoid will not be
grounded.
YES
NO
Repair wire 1435
(see schematic Fig
2-65) or notify DS
Maintenance.
Verify repair, go to
Step 6 of this Fault.
5.
Is continuity measured on
wire 1435 between main
supply valve solenoid
connector MC123, terminal 2
and a known good ground?
Fault not corrected.
Notify DS
Maintenance.
WARNING
WINCH/CRANE switch is in
WINCH position.
AUX HYD light L27 operates.
Crane operates.
Hoses 2809, 2899 and 2886 OK.
Control manifold OK.
WINCH/CRANE switch OK.
Wire 1732 OK.
Wire 1435 OK.
KNOWN INFO
POSSIBLE PROBLEMS
TEST OPTIONS
REASON FOR QUESTION
Verify repair.
If winch operates correctly, the
fault is corrected.
YES
NO
Fault not corrected.
Notify DS
Maintenance.
6.
Does winch operate correctly
when operating the control
lever?
Fault corrected.
Read WARNING
on Page 2-2823
|