TM 9-2320-364-20-3
2-2871
(1) Set hydraulic selector switch to
WINCH/CRANE position.
(2) Is there continuity between
hydraulic selector switch, terminal
21 and 22?
(a) If there is no continuity, replace
the hydraulic selector switch
(Para 7-31).
(b) If there is continuity, hydraulic
selector switch is OK.
(3) Install instrument panel and sunshield
with ten screws.
(4) Install ECB side panel with six
screws.
CONTINUITY TEST
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive electrical
circuits, a direct short may result. Damage to equipment and injury or death to personnel may occur.
|