TM 9-2320-364-20-3      2-2875 (1)   START engine (TM 9-2320-364-10). (2)   Remove cap from SRW control manifold supply override. (3)   Rotate manual override to unlock and pull up. (4)   Operate SRW using manual control. (a)   If SRW does not operate, problem is hydraulic.  Perform Steps (5) through (7) below and go to Step 5 of this Fault. (b)   If SRW operates, problem is electrical. (5)   Push down on manual override and rotate to lock in down position. (6)   Install cap on manual override. (7)   Turn OFF ENGINE switch. MANUAL OVERRIDE TEST