TM 9-2320-364-20-4
2-3046
1. ARCTIC KIT WATER PUMP DOES NOT OPERATE (CONT).
4.
Is continuity measured from
relay R32, terminal 30, to
arctic heater switch harness
connector, terminal 5?
Repair wire 1431 (see
schematic Fig 2-74)
or notify DS
Maintenance.
Verify repair, go to
Step 11 of this Fault.
YES
NO
Arctic batteries OK.
Blackout stop lights operate
indicting CB20 is OK.
Wire 1435 OK.
Water pump OK.
Wire 1431 from connector
MC119 to CB20 OK.
Wire 1431 between relays R32
and arctic heater switch faulty.
Relay R32 faulty.
Arctic heater switch faulty.
Wire 1644 faulty.
Relay R33 not grounded.
Relay R33 faulty.
Wire 1644 to water pump
faulty.
KNOWN INFO
POSSIBLE PROBLEMS
TEST OPTIONS
REASON FOR QUESTION
Continuity test.
STE/ICE-R #91.
If continuity is not present, wire
1431 is faulty.
WARNING
5.
Are 22 to 28 vdc measured on
wire 1431 at arctic heater
switch harness connector,
terminal 5?
Replace relay
R32 (Para 7-95).
Verify repair, go to
Step 11 of this Fault.
YES
NO
Arctic batteries OK.
Blackout stop lights operate
indicating CB20 is OK.
Wire 1435 OK.
Water pump OK.
Wire 1431 from connector
MC119 to relay CB20 OK.
Wire 1431 between relays R32
and arctic heater switch OK.
Relay R32 faulty.
Arctic heater switch faulty.
Wire 1644 faulty.
Relay R33 not grounded.
Relay R33 faulty.
Wire 1644 to water pump faulty.
KNOWN INFO
POSSIBLE PROBLEMS
TEST OPTIONS
REASON FOR QUESTION
Voltage test.
STE/ICE-R #89.
If 22 to 28 vdc are not present,
relay R32 is faulty.
WARNING
Read WARNING
on Page 2-3047
Read WARNING
on Page 2-3047
|