TM 9-2320-364-20-4
12-125
(4)
Install reducer (36) and drain valve (35) on
air reservoir (5).
Adhesives, solvents, and sealing
compounds can burn easily, can
give off harmful vapors, and are
harmful to skin and clothing. To
avoid injury or death, keep away
from open fire and use in well-
ventilated area. If adhesive,
solvent, or sealing compound
gets on skin or clothing, wash
immediately with soap and
water.
(5)
Coat threads of reducer (34) and fitting (11)
with sealing compound.
(6)
Install reducer (34) and fitting (11) on air
reservoir (5).
(7)
Coat threads of elbow (33) and reducer (32)
with sealing compound.
(8)
Install elbow (33) and reducer (32) on air
reservoir (5).
(9)
Coat threads of check valve (31) and
fitting (9) with sealing compound.
(10)
Install check valve (31) and fitting (9) on
reducer (32).
(11)
Coat threads of plug (37) with sealing
compound.
(12)
Install plug (37) on air reservoir (5).
(13)
Remove air reservoir (5) from vise.
|