TM 9-2320-364-20-4
2-3075
(1) Start engine (TM 9-2320-364-10).
(2) Open manual override button on
auxillary supply valve solenoid by
pulling out past notches and turning
clockwise.
(3) Set hydraulic selector switch to
CRANE/SRW position.
(4) Operate Interface:
(a) If interface does not operate, perform
Steps (5) thru (7) below and replace
auxiliary supply valve (Para 21-17)
and go to Step 21 of this Fault.
(b) If interface operates, perform Steps
(5) thru (7) below and replace auxiliary
supply valve solenoid (Para 21-17),
and go to Step 21 of this Fault.
(5) Set hydraulic selector switch to OFF
position.
(6) Shut off engine.
(7) Close auxiliary supply valve solenoid
valve manual override button.
MANUAL OVERRIDE TEST
High pressure hydraulics [oil under 3700 psi
(25,512 kPa) pressure] operate this equipment.
Refer to vehicle operator and maintenance
manuals for hydraulic oil pressure. Never
disconnect any hydraulic line or fittings without
first dropping pressure to zero. A high
pressure oil stream can pierce body and cause
severe injury to personnel.
AUXILIARY
SUPPLY VALVE
NOTCHES
AUXILIARY
SUPPLY VALVE
MANUAL
OVERRIDE
BUTTON
|